CO2 Incubator ICO




Title : CO2 Incubator ICO

Content : For the protection of cell cultures, bacteria cultures or tissue cultures CO2 Incubator ICO The control system of the Memmert CO2 incubator ICO is so finely tuned that the appliance reaches the setpoint temperature very quickly and without temperature overshoots. Alarm notifications to your mobile phone guarantee the safety of the chamber load, and the battery-buffered ControlCOCKPIT ensures continuous CO2 control even when there is a power failure. Ideal hygiene is a given too: rounded edges enable easy and thorough cleaning, the interior can be sterilised within 60 minutes at 180 °C. 4 model sizes (with a chamber volume of 56 to 241 litres) Temperature range +18 °C to +50 °C Setting range CO2 0 to 20 % CO2 Setting range 02 1 to 20 % O2 Setting range active humidity control (with option K7) 40 to 97 and rh-off Fail-safe, FDA-compliant logging of temperature, CO2, O2 humidity, open door time data Battery-buffered ControlCOCKPIT: The operating display, logging and CO2 control are fully functional even during a power failure Visual and acoustic alarm as well as alarm notification to mobile phones if the individually adjustable temperature, CO2, O2, or humidity ranges are exceeded Active humidity control The interior chamber, including all installations and sensors, can be sterilised at +180 °C in a 60-minute programme




Title : ICO5O

Content : Working-temperature range: 5 °C above ambient temperature up to +50 °C. Volume 56 l. CO2 control Digital electronic CO2 control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation. Standard sterilisation programme: 60 minutes at 180°C (without removing the sensors). Door fully insulated stainless steel door with 2-point locking (compression door lock), inner glass door with opening (8 mm Ø) to take gas sample.




Title : ICO105

Content : Working-temperature range 5 °C above ambient temperature up to +50 °C Standard sterilisation programme: 60 minutes at 180°C (without removing the sensors). Volume 107 l. Max. number of internals 6. Alarm visual and acoustic.




Title : ICO150

Content : Working-temperature range 5 °C above ambient temperature up to +50 °C Standard sterilisation programme: 60 minutes at 180°C (without removing the sensors). Volume 156 l. Max. number of internals 10.




Title : ICO150

Content : Working-temperature range 5 °C above ambient temperature up to +50 °C Standard sterilisation programme: 60 minutes at 180°C (without removing the sensors). Volume 156 l. Max. number of internals 10.




Title : ICO240

Content : Working-temperature range 5 °C above ambient temperature up to +50 °C Standard sterilisation programme: 60 minutes at 180°C (without removing the sensors). Volume 241 l. CO2 control Digital electronic CO2 control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation. Alarm visual and acoustic